<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>HOCHIKI &#8211; NN CONTROLS</title>
	<atom:link href="https://nncontrols.com/product-category/fire-detection/hochiki/feed/" rel="self" type="application/rss+xml" />
	<link>https://nncontrols.com</link>
	<description></description>
	<lastBuildDate>Thu, 13 Aug 2026 10:49:05 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://nncontrols.com/wp-content/uploads/2024/01/cropped-NNCONTROLS-ICON-1-32x32.png</url>
	<title>HOCHIKI &#8211; NN CONTROLS</title>
	<link>https://nncontrols.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Hochiki IR3 / IR3-IS / IR3-EX INFRA-RED Flame Detector</title>
		<link>https://nncontrols.com/product/hochiki-ir3-ir3-is-ir3-ex-infra-red-flame-detector/</link>
					<comments>https://nncontrols.com/product/hochiki-ir3-ir3-is-ir3-ex-infra-red-flame-detector/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 15 Jan 2024 16:33:04 +0000</pubDate>
				<guid isPermaLink="false">https://nncontrols.com/?post_type=product&#038;p=1864</guid>

					<description><![CDATA[STANDARD FEATURES • Choices of Infra-Red Flame Detector are IR3, IR3-EX (Explosion Proof), IR3-IS (Intrinsically Safe) • LPCB Listed and Certified to EN54-10 • Certified to II 2 G D • Range of view up to 25m (82 ft.) • Reduces false alarm by built-in combination filters and signal processing techniques • Operates even if [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>STANDARD FEATURES<br />
• Choices of Infra-Red Flame Detector are IR3, IR3-EX (Explosion Proof), IR3-IS (Intrinsically Safe)<br />
• LPCB Listed and Certified to EN54-10<br />
• Certified to II 2 G D<br />
• Range of view up to 25m (82 ft.)<br />
• Reduces false alarm by built-in combination filters and signal processing techniques<br />
• Operates even if the lens is contaminated by a layer or oil, dust, water-vapor or ice</p>
]]></content:encoded>
					
					<wfw:commentRss>https://nncontrols.com/product/hochiki-ir3-ir3-is-ir3-ex-infra-red-flame-detector/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Hochiki FIRElink-100 High Sensitivity Air Sampling Smoke Detector</title>
		<link>https://nncontrols.com/product/hochiki-firelink-100-high-sensitivity-air-sampling-smoke-detector/</link>
					<comments>https://nncontrols.com/product/hochiki-firelink-100-high-sensitivity-air-sampling-smoke-detector/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 15 Jan 2024 16:29:05 +0000</pubDate>
				<guid isPermaLink="false">https://nncontrols.com/?post_type=product&#038;p=1862</guid>

					<description><![CDATA[Ultra small, low cost aspirating smoke detector for easy and discreet installation High sensitivity provided by laser based forward light scatter for reliable early warning Two sampling pipes up to 100 m (aggregate) in length (still air) False alarms reduced by unique laser sensing technology &#8211; able to discriminate against dust RS485 communications built in [&#8230;]]]></description>
										<content:encoded><![CDATA[<ul>
<li>Ultra small, low cost aspirating smoke detector for easy and discreet installation</li>
<li>High sensitivity provided by laser based forward light scatter for reliable early warning</li>
<li>Two sampling pipes up to 100 m (aggregate) in length (still air)</li>
<li>False alarms reduced by unique laser sensing technology &#8211; able to discriminate against dust</li>
<li>RS485 communications built in as standard for networking and remote communications</li>
</ul>
]]></content:encoded>
					
					<wfw:commentRss>https://nncontrols.com/product/hochiki-firelink-100-high-sensitivity-air-sampling-smoke-detector/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Hochiki FN-600ULX Power Supply/Charger</title>
		<link>https://nncontrols.com/product/hochiki-fn-600ulx-power-supply-charger/</link>
					<comments>https://nncontrols.com/product/hochiki-fn-600ulx-power-supply-charger/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 15 Jan 2024 16:25:08 +0000</pubDate>
				<guid isPermaLink="false">https://nncontrols.com/?post_type=product&#038;p=1860</guid>

					<description><![CDATA[STANDARD FEATURES • Cost Effective • Filtered and Electronically Regulated Output • AC Fail Supervision (Form C), Low Battery Supervision (Form C) and Battery Supervision (Form C) • Built In Charger for Sealed Lead Acid or Gel Type Batteries • Accommodates (2) 12VDC/7AH batteries]]></description>
										<content:encoded><![CDATA[<p><strong>STANDARD FEATURES</strong><br />
• Cost Effective<br />
• Filtered and Electronically Regulated Output<br />
• AC Fail Supervision (Form C), Low Battery Supervision (Form C) and Battery Supervision (Form C)<br />
• Built In Charger for Sealed Lead Acid or Gel Type Batteries<br />
• Accommodates (2) 12VDC/7AH batteries</p>
]]></content:encoded>
					
					<wfw:commentRss>https://nncontrols.com/product/hochiki-fn-600ulx-power-supply-charger/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Hochiki PE-6SN Power Extender</title>
		<link>https://nncontrols.com/product/hochiki-pe-6sn-power-extender/</link>
					<comments>https://nncontrols.com/product/hochiki-pe-6sn-power-extender/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 15 Jan 2024 16:22:09 +0000</pubDate>
				<guid isPermaLink="false">https://nncontrols.com/?post_type=product&#038;p=1858</guid>

					<description><![CDATA[120/240 VAC 50/60 Hz Input PE-6SN offers 6 amps, PE-10SN offers 10 amps Two (2) Trouble Relays Two (2) Class A or B trigger circuit One (1) Programmable AUX power rated @ 3 amps Quadrasync provides panel wide synchronization of the same or multiple brands Pass Thru mode allows the Outputs to match the Input [&#8230;]]]></description>
										<content:encoded><![CDATA[<ul>
<li>120/240 VAC 50/60 Hz Input</li>
<li>PE-6SN offers 6 amps, PE-10SN offers 10 amps</li>
<li>Two (2) Trouble Relays</li>
<li>Two (2) Class A or B trigger circuit</li>
<li>One (1) Programmable AUX power rated @ 3 amps</li>
<li>Quadrasync provides panel wide synchronization of the same or multiple brands</li>
<li>Pass Thru mode allows the Outputs to match the Input Signal</li>
<li>Signal Circuit Trouble Memory – Facilitates quickly locating intermittent system trouble and eliminated costly and unnecessary service calls. LED’s indicate a prior fault (short, open, ground) has occurred on one or more signaling circuit outputs.</li>
<li>Horn/Strobe sync protocols include: Gentex, System Sensor, Wheelock and Amseco/Potter.</li>
<li>Temporal Code 3 Mode</li>
<li>Configurable output circuits (DIP switch sets options for each circuit)</li>
<li>15 mA at 8-33 VDC input trigger</li>
<li>Reference EOL allows 2K-27K EOL value to be used</li>
<li>AC fail, battery presence &amp; low battery monitoring</li>
<li>Supports 7 – 55AH batteries</li>
<li>Accommodates up to two (2) 12VDC/18AH batteries</li>
<li>Power supply, logic board, red enclosure, cam lock (CAT30), transformer &amp; battery leads</li>
</ul>
]]></content:encoded>
					
					<wfw:commentRss>https://nncontrols.com/product/hochiki-pe-6sn-power-extender/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Hochiki HE Series Selectable Candela Evacuation Signals</title>
		<link>https://nncontrols.com/product/hochiki-he-series-selectable-candela-evacuation-signals/</link>
					<comments>https://nncontrols.com/product/hochiki-he-series-selectable-candela-evacuation-signals/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 15 Jan 2024 16:18:11 +0000</pubDate>
				<guid isPermaLink="false">https://nncontrols.com/?post_type=product&#038;p=1856</guid>

					<description><![CDATA[STANDARD FEATURES • Nominal voltage 12VDC and 24VDC • 24VDC units have field selectable candela options of 15, 30, 60, 75, and 110 candela • 12VDC units have field selectable candela options of 15, 30, 60, and 75 candela • Unit Dimensions: 5&#8243; high x 4.5&#8243; wide x 2.5&#8243; deep • Synchronize strobe and/or horn [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>STANDARD FEATURES<br />
• Nominal voltage 12VDC and 24VDC<br />
• 24VDC units have field selectable candela options of 15, 30, 60, 75, and 110 candela<br />
• 12VDC units have field selectable candela options of 15, 30, 60, and 75 candela<br />
• Unit Dimensions: 5&#8243; high x 4.5&#8243; wide x 2.5&#8243; deep<br />
• Synchronize strobe and/or horn with Hochiki Series Control Module (12VDC product must use the HAVSM Module)<br />
• Prewire entire system, then install signals<br />
• Lower installation and operating costs<br />
• Input terminals supports 12 to 18 gauge wire<br />
• Switch selection for high or low dBA<br />
• Switch for chime, whoop, mechanical and 2400Hz tone<br />
• Switch for continuous or temporal 3 (not available on whoop tone)<br />
• Surface mount with the HSB (Hochiki surface mount box)<br />
• Silence horn while strobes remain flashing<br />
• Wide voltage range 8-17.5VDC (12VDC units) 16-33VDC or FWR (24VDC units)<br />
• Faceplate available in red or off-white<br />
Product Compliance<br />
• NFPA 72<br />
• Americans with Disabilities Act (ADA)</p>
]]></content:encoded>
					
					<wfw:commentRss>https://nncontrols.com/product/hochiki-he-series-selectable-candela-evacuation-signals/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Hochiki DCP-AMS SERIES Addressable Manual Pull Stations</title>
		<link>https://nncontrols.com/product/hochiki-dcp-ams-series-addressable-manual-pull-stations/</link>
					<comments>https://nncontrols.com/product/hochiki-dcp-ams-series-addressable-manual-pull-stations/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 15 Jan 2024 16:11:27 +0000</pubDate>
				<guid isPermaLink="false">https://nncontrols.com/?post_type=product&#038;p=1854</guid>

					<description><![CDATA[Features &#38; Specifications &#160; &#8211; Single and dual-action models are available &#8211; Bi-colored status LED indicates Standby and Alarm conditions &#8211; Address can be programmed when installed &#8211; Key lock or hex key-lock models are available &#8211; ADA compliant (except LP models) &#160; Operating Voltage (SLC): 17~41 VDC Average Current Consumption: 550uA (Typical) &#124; 660uA (Alarm) Ambient [&#8230;]]]></description>
										<content:encoded><![CDATA[<h3>Features &amp; Specifications</h3>
<p>&nbsp;</p>
<p>&#8211; Single and dual-action models are available</p>
<p>&#8211; Bi-colored status LED indicates Standby and Alarm conditions</p>
<p>&#8211; Address can be programmed when installed</p>
<p>&#8211; Key lock or hex key-lock models are available</p>
<p>&#8211; ADA compliant (except LP models)</p>
<p>&nbsp;</p>
<p>Operating Voltage (SLC): 17~41 VDC<br />
Average Current Consumption: 550uA (Typical) | 660uA (Alarm)<br />
Ambient Temperature: 32°F (0 °C) ~ 120°F (49°C)<br />
Maximum Humidity: 90% RH, non-condensing<br />
Dimensions: 3.4&#8243;W x 4.8&#8243;H x 2.0&#8243;D<br />
Mounting: Single gang or 4&#8243; square electrical box</p>
]]></content:encoded>
					
					<wfw:commentRss>https://nncontrols.com/product/hochiki-dcp-ams-series-addressable-manual-pull-stations/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Hochiki DCP-CZM Conventional Zone Module</title>
		<link>https://nncontrols.com/product/hochiki-dcp-czm-conventional-zone-module/</link>
					<comments>https://nncontrols.com/product/hochiki-dcp-czm-conventional-zone-module/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 15 Jan 2024 16:05:48 +0000</pubDate>
				<guid isPermaLink="false">https://nncontrols.com/?post_type=product&#038;p=1852</guid>

					<description><![CDATA[Features &#38; Specifications &#160; &#8211; UL 864 9th Edition Listed &#8211; Provides an address point for a zone of up to 25 conventional smoke detectors &#8211; Blinks green when polled. Latched on red (controlled by panel) when activated &#8211; Device address can be programmed with a handheld programmer. Device address- ranges from 1 to 127 [&#8230;]]]></description>
										<content:encoded><![CDATA[<h3>Features &amp; Specifications</h3>
<p>&nbsp;</p>
<p>&#8211; UL 864 9th Edition Listed</p>
<p>&#8211; Provides an address point for a zone of up to 25 conventional smoke detectors</p>
<p>&#8211; Blinks green when polled. Latched on red (controlled by panel) when activated</p>
<p>&#8211; Device address can be programmed with a handheld programmer. Device address- ranges from 1 to 127</p>
<p>&#8211; Compatible with Class B and Class A wiring</p>
<p>&nbsp;</p>
<p>Supply Voltage (S-SC): 25.3 ~ 39 VDC<br />
Auxiliary Supply Voltage: 18.8 ~ 27.2 VDC<br />
Average Current Consumption: 670µA<br />
2-Wire Detector Loop Current: 1mA Max.<br />
From Auxiliary Supply: 60mA Max.<br />
EOL Device: 4.7 ohms Resistor<br />
Max. Quantity Per Loop: 127<br />
Alarm Threshold Level:</p>
<p>Wiring Threshold Level: &gt;2.5K ohms &amp;</p>
<p>Open Circuit Threshold Level: &gt;10K ohms</p>
]]></content:encoded>
					
					<wfw:commentRss>https://nncontrols.com/product/hochiki-dcp-czm-conventional-zone-module/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Hochiki DCP-R2ML/-I &#038; DCP-R2MH/-I Dual Relay Module</title>
		<link>https://nncontrols.com/product/hochiki-dcp-r2ml-i-dcp-r2mh-i-dual-relay-module/</link>
					<comments>https://nncontrols.com/product/hochiki-dcp-r2ml-i-dcp-r2mh-i-dual-relay-module/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 15 Jan 2024 16:02:23 +0000</pubDate>
				<guid isPermaLink="false">https://nncontrols.com/?post_type=product&#038;p=1850</guid>

					<description><![CDATA[Provides two independently configurable Form C contacts per address &#8211; Contacts are rated as follow: + R2ML: 2A @ 30 VDC / 0.5A @ 120 VAC + R2MH: 8A @ 30VDC / 4.8A @ 250 VAC &#8211; Up to127 devices can be used on each SLC loop &#8211; Visible Bi-colored LED is software controlled and [&#8230;]]]></description>
										<content:encoded><![CDATA[<div>
<div>Provides two independently configurable Form C contacts per address</div>
<div>&#8211; Contacts are rated as follow:</div>
<div>+ R2ML: 2A @ 30 VDC / 0.5A @ 120 VAC</div>
<div>+ R2MH: 8A @ 30VDC / 4.8A @ 250 VAC</div>
<div>&#8211; Up to127 devices can be used on each SLC loop</div>
<div>&#8211; Visible Bi-colored LED is software controlled and can be programmed to blink red or green when polled. The LED can be latched on when activated. (For All Models)</div>
<div>&#8211; Yellow LED indicates a short circuit condition (R2ML-I &amp; R2MH-I only)</div>
<div>&#8211; Programming is highly flexible providing 16 priority states plus zoning capability</div>
<div>&#8211; Operates on Class A or Class B SLC loop</div>
</div>
<p>&#8211; UL 864 Listed</p>
]]></content:encoded>
					
					<wfw:commentRss>https://nncontrols.com/product/hochiki-dcp-r2ml-i-dcp-r2mh-i-dual-relay-module/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Hochiki DCP-DIMM Dual Input Monitor Module</title>
		<link>https://nncontrols.com/product/hochiki-dcp-dimm-dual-input-monitor-module/</link>
					<comments>https://nncontrols.com/product/hochiki-dcp-dimm-dual-input-monitor-module/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 15 Jan 2024 15:50:08 +0000</pubDate>
				<guid isPermaLink="false">https://nncontrols.com/?post_type=product&#038;p=1848</guid>

					<description><![CDATA[Features &#38; Specifications &#160; &#8211; UL 864 9th Edition Listed &#8211; Fast, reliable contact monitoring utilizing the Hochiki DCP (Digital Communications Protocol) &#8211; 127 devices can be used per DCP loop &#8211; Bi-colored indicating LED provides module status &#8211; Dual input contact monitor &#160; Supply Voltage (S-SC): 25.3 ~ 39 VDC Average Current Consumption: 600µA (Typical) &#124; [&#8230;]]]></description>
										<content:encoded><![CDATA[<h3>Features &amp; Specifications</h3>
<p>&nbsp;</p>
<p>&#8211; UL 864 9th Edition Listed</p>
<p>&#8211; Fast, reliable contact monitoring utilizing the Hochiki DCP (Digital Communications Protocol)</p>
<p>&#8211; 127 devices can be used per DCP loop</p>
<p>&#8211; Bi-colored indicating LED provides module status</p>
<p>&#8211; Dual input contact monitor</p>
<p>&nbsp;</p>
<p>Supply Voltage (S-SC): 25.3 ~ 39 VDC<br />
Average Current Consumption: 600µA (Typical) | 720µA (Alarm)<br />
Programmable Inputs: 2 Independent Monitoring Inputs<br />
EOL Device: 22K ohms Resistor<br />
Max. Quantity Per Loop: 127<br />
Dimensions: 4.2”W x 4.7”H x 1.4”D<br />
Operating Temperature: 32°F (0°C) ~ 120°F (49°C)<br />
Mounting: 4” square electrical box<br />
Relative Humidity: 90% RH Non-Condensing</p>
<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://nncontrols.com/product/hochiki-dcp-dimm-dual-input-monitor-module/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Hochiki ASB Analog Sounder Base</title>
		<link>https://nncontrols.com/product/hochiki-asb-analog-sounder-base/</link>
					<comments>https://nncontrols.com/product/hochiki-asb-analog-sounder-base/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Mon, 15 Jan 2024 15:47:14 +0000</pubDate>
				<guid isPermaLink="false">https://nncontrols.com/?post_type=product&#038;p=1846</guid>

					<description><![CDATA[STANDARD FEATURES • Programmable evacuation codes &#8211; Continuous, March, ANSI Temporal patterns • Base learns the sensor address and assumes an upper range address (128-254) • Up to 127 sensors and 127 ASBs can be used on one SLC loop • Can be alarmed or reset by zone or by individual address • ASB SLC [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><strong>STANDARD FEATURES</strong><br />
• Programmable evacuation codes &#8211; Continuous, March, ANSI Temporal patterns<br />
• Base learns the sensor address and assumes an upper range address (128-254)<br />
• Up to 127 sensors and 127 ASBs can be used on one SLC loop<br />
• Can be alarmed or reset by zone or by individual address<br />
• ASB SLC loop wire resistance = 50 ohms Max.(total SLC wire run length)<br />
• High sound pressure level (85dB SPL at 10 feet)</p>
]]></content:encoded>
					
					<wfw:commentRss>https://nncontrols.com/product/hochiki-asb-analog-sounder-base/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
